Your Funiki air conditioner is operating abnormally, accompanied by strange symbols such as F1, F2, E4, ... appearing on the screen? Don't worry too much! What you need to do now is look up the error code table of Funiki air conditioners below to find the cause and the most accurate solution.
Table of Contents
Funiki air conditioner error code |
Model |
Error name |
How to fix |
E01 |
FC45M, FH45M |
10 Kohm air sensor error. Air conditioner does not work, phenomenon similar to power loss. |
Contact technical staff for support. |
E02 |
FC45D, FH45D |
Indoor unit high temperature protection sensor is broken (compressor not running). Need to check sensor and gas. |
Check sensor and gas. |
E02 |
FC, FH45 |
Only indoor fan running, low pressure valve error, high pressure, phase deviation. |
Contact technical staff for support. |
E02 |
FC45M, FH45M |
10 kohm sensor error. |
Contact technical staff for support. |
E03 |
FC45D, FH45D |
Indoor unit anti-freeze protection sensor error (block not running). Carefully check sensor, check gas. |
Check gas and sensor. |
E03 |
FC45M, FH45M |
10 Kohm outdoor sensor error. Can be reconnected and the machine will still run normally. |
The circuit can be short-circuited. |
E04 |
FC45D, FH45D |
Gas loss protection error, only the evaporator fan is running. Fix by leaking and refilling gas. |
Can leak and refill gas for air conditioner. |
E05 |
FC, FH45 |
Air sensor error, coil sensor error (run for 45 minutes, stop for 10 minutes). |
Contact technical staff for support. |
E06 |
FC, FH45 |
Evaporator sensor error (on for 45 minutes, off for 10 minutes). Check 10 Kohm probe and connector. |
Check high pressure, low pressure due to cable blockage, check gas for excess or shortage. |
E06 |
FC45M, FH45M |
Wrong phase, phase protector failure, check high pressure, low pressure due to cable blockage, excess gas or lack of gas. |
Check the 10 kOhm probe and sensor connector. |
E07 |
FC, FH45 |
Condenser sensor error. Fix by checking the 10 Kohm probe and the connector, the probe can be short-circuited at the control board. |
Check the 10 kOhm probe and the air conditioner connector; fix by short-circuiting the probe on the control board. |
E09 |
FC, FH45 |
Only the evaporator fan is running, possibly due to lack of gas or incorrect evaporator sensor value. |
Contact technical staff for support. |
E1 |
FC, FH24M |
Air sensor error. |
Contact technical staff for support. |
E2 |
FC24M, FH24M, FC27M, FH27M |
Sensor error. |
Contact technical staff for support. |
E3 |
FC45D, FH45D |
Evaporator sensor error. |
Contact technical staff for support. |
E4 |
Squirrel cage fan error does not run due to jamming or damage. |
Contact technical staff for support. |
|
E5 |
Air sensor broken or shorted; connector loose or damaged. |
Contact technical staff for support. |
|
E5 |
FC24, FH24, FC27, FH27 |
Wrong sensor or low gas system. |
Contact technical staff for support. |
E5 |
FC45D, FH45D |
Air sensor error (on 45 minutes, off 10 minutes). |
Contact technical staff for support. |
E6 |
Sensor error is broken or short-circuited, plug is loose or damaged. |
Contact technical staff for support. |
|
E6 |
FC24, FH24, FC27, FH27 |
Air sensor error (on 45 minutes, off 10 minutes). |
Contact technical staff for support. |
E6 |
FC45D, FH45D |
Evaporator sensor error (on for 45 minutes, off for 10 minutes). |
Replace the evaporator sensor with the correct value. |
E7 |
FC24, FH24, FC27, FH27 |
Error in sensor, wire, plug (on for 45 minutes, off for 10 minutes). |
Contact technical staff for support. |
E9 |
Gas shortage error; voltage voltage; sensor error value. |
Contact technical staff for support. |
|
FC |
Reset button is stuck |
Check the Reset button and remote control. Using the remote control to increase or decrease the air conditioner temperature will fix the problem. |
|
FF4 |
FC, FH27G |
High temperature protection sensor error; need to check connector, sensor and gas. |
Check and fix the plug, sensor or gas. |
FF7 |
FC, FH27G |
Air sensor error, sensor resistance 5 Kohm. |
Contact technical staff for support. |
FF8 |
FC, FH27G |
Error in the sensor, 5 Kohm sensor. Need to check the gas and plug. |
Check plug and gas. |
F4 |
High temperature protection sensor error, machine stops all operations. |
Check the plug, sensor and gas. |
|
EC |
New Funiki air conditioners after 2019 |
The engine block is overheating, out of gas or the circuit board is damaged. |
Check engine block, internal gas or replace circuit board. |
E3 |
Error in the indoor unit's anti-freeze protection sensor (block stops working). |
Check the sensor and gas level in the machine. |
|
E4 |
Fan or motherboard error. |
Check the fan and circuit board to see if they can be reconnected or need to be replaced. |
>> Share :
Thus, we have provided you with a detailed table of Funiki air conditioner error codes. Use it to determine the "disease" your device is suffering from and find a timely solution.
In the errors in the table above, E4 and E6 are the most common codes.
The evaporator fan (evaporator squirrel cage fan) is not working or does not send pulses to the microprocessor. To fix this problem, you first need to check if the fan is working properly. If the fan is still working properly, the motherboard is most likely damaged. If the fan does not run, it is most likely due to a power supply or a broken evaporator fan.
This is an evaporator sensor error. If the Funiki air conditioner reports error E6, you should replace the evaporator sensor with the correct type and value.
Error E3 on Funiki air conditioner shows that the anti-frost protection sensor on the evaporator is broken, usually appearing after about 3-5 minutes right after you start the air conditioner. At that time, the word E3 appears right on the LED screen and the evaporator fan stops working.
The cause of error E3 on Funiki air conditioner is due to damaged components after a period of use or the air conditioner is low/out of gas.
How to fix error E3 Funiki air conditioner:
Step 1: Remove the Funiki air conditioner's mask cover with a screwdriver to check if the fan's power cord is broken.
Step 2: Check if the evaporator fan capacitor is damaged by using an electric meter. If the evaporator fan capacitor is damaged, replace it with a new capacitor of the same value.
Step 3: Check if the evaporator fan is broken, if broken, replace the fan.
Step 4: After checking all the above causes but the Funiki air conditioner still displays error E3, the air conditioner is out of gas or the control circuit is broken.
Step 5: Check the air conditioner gas by turning on the air conditioner at the temperature you want to set, check if the correct cooling mode is selected or not. If the air conditioner does not emit cool air, the air conditioner may be out of gas.
Step 6: Check to see if the condenser fan is spinning and if there is heat coming out of the condenser when the air conditioner is running?
Step 7: Check the air conditioner sensor. You should only do this yourself if you have expertise.
How to fix error E3 Funiki air conditioner is quite complicated and difficult to solve. To avoid more serious damage, please contact the warranty or experienced and professional technical teams for support.
Hopefully our sharing about Funiki air conditioner error codes and how to fix some common problems will help you more or less. Visit META.vn if you need more advice about Funiki air conditioners.
>>> See more :
Microsoft Edge browser has a hidden Circle To Copilot feature, circle something to search on Copilot like with Samsung's Circle to Search feature.
Kungfu Hero Code gives players Kim Nguyen Bao, EXP Pills, Summon Chests, Speed Up Tickets and many other rewards.
The research tool in Excel is activated by Alt + left mouse button. If you do not need to use research in Excel, you can completely disable this tool according to the instructions below.
The US Naval Research Laboratory (NRL) has successfully transmitted 1.6 kW of wireless power over a distance of 1 km using microwaves.
Scientists have discovered a new climate phenomenon similar to El Nino, which could cause temperature changes across the Southern Hemisphere.
The fact that top browsers are starting to use AI to prevent scams is good news for users.
Files by Google will now automatically enable Gemini analysis when you open a PDF document.
Windows 11 has a lot of features, but it also has some quirks. You can easily fix some of those issues—and take advantage of new features and mods—with third-party tools like Windhawk.
Nunu of the new season of Truth Arena has a skill similar to Singed DTCL season 2 and Aurelion Sol of season 3 but the movement range will be wider and the speed will also be faster.
To quickly use ChatGPT on Edge browser, you can add it to the right Sidebar of the browser for immediate use when needed.
In 2023, a series of AIs that create images with just a short description were released, including OpenAI's Dall-E, Stability.AI's Stable Diffusion, and Meta's Midjourney, Imagine with Meta AI.
The ability to copy and paste is a basic, simple function that any operating system has and must have.
OnePlus phones have three ways to take screenshots, including taking scrolling screenshots without additional software.
The tool used to customize Windows 11, Start11, offers a free trial and then charges a one-time fee of $9.99.